What makes the Klargester BioDisc different from an ordinary sewage treatment plant? The answer lies in how it treats your wastewater, and it might not be what you expect.
Designed for properties without a mains foul sewer connection, the Klargester BioDisc sewage treatment plant uses a rotating biological contactor (RBC) rather than a conventional aeration blower to support the treatment process. But there is more to owning one than understanding how it works.
From choosing the correct size and arranging installation to managing electricity, desludging, servicing and legal discharge requirements, several factors influence its performance.
So, how does the BioDisc actually work, and what should you know before installing or maintaining one? This guide covers its different sizes, operating requirements, common problems and UK regulations to help you make informed decisions.
What Is a Klargester BioDisc?
The Klargester BioDisc is a packaged sewage treatment plant designed to treat domestic wastewater through mechanical and biological processes. It combines settlement chambers with a powered treatment system to reduce pollutants before the treated effluent leaves through a suitable discharge route.
The system uses Rotating Biological Contactor (RBC) technology, where discs turn slowly between wastewater and air. Microorganisms growing on these surfaces break down organic matter. The domestic Klargester BioDisc range includes four models with treatment capacities from 6 to 18 population equivalents (PE), while larger units serve properties with greater wastewater demands.
Unlike a BioDisc, a conventional septic tank has no powered biological treatment mechanism. It primarily separates solids and partially breaks down waste, with further treatment taking place in a drainage field. This distinction also affects the permitted wastewater discharge arrangements in England.
How Does a Klargester BioDisc Work?
The Klargester BioDisc treats sewage through four stages, combining settlement with biological treatment to remove organic pollutants and suspended solids before discharge.
1. Primary Settlement
Incoming wastewater enters the primary settlement chamber, where heavier solids sink and form sludge. Fats, grease and other floating materials remain near the surface, while the settled liquid moves towards biological treatment.
This separation reduces the solid load reaching the rotating discs and helps prevent excessive accumulation of waste in the treatment zones. The collected sludge requires periodic removal to maintain sufficient settlement capacity.
2. Biological Treatment on the Rotating Discs
The BioDisc uses Rotating Biological Contactor (RBC) technology, consisting of discs partially submerged in wastewater. Microorganisms develop a biofilm on their surfaces and consume biodegradable organic matter.
An electric motor slowly rotates the discs, exposing the microorganisms alternately to wastewater and atmospheric oxygen. This supports aerobic biological treatment without the conventional blower and diffuser arrangement used in many other sewage treatment plants.
The rotating discs provide a continuous surface for biological growth, allowing wastewater treatment to continue as sewage passes through the unit.
3. Further Biological Treatment and Flow Management
Wastewater then passes through a second biological treatment zone, where additional microorganisms break down remaining organic pollutants.
The Klargester BioDisc system also incorporates a managed flow arrangement that helps regulate wastewater transfer between treatment stages.
Rather than passing every sudden increase in incoming flow directly through the plant, this arrangement temporarily accommodates variations in wastewater volume. It helps maintain steadier conditions for biological treatment, particularly during periods of higher household water usage.
4. Final Settlement and Treated Effluent
Following biological treatment, wastewater enters the final settlement chamber. Here, biological solids that have detached from the discs settle out, while clarified liquid moves towards the outlet.
The system returns settled biological sludge towards the primary settlement area, where it accumulates for eventual removal.
Treated effluent then leaves through an appropriate discharge arrangement, such as a suitable drainage field or a permitted surface water outlet.
In England, the general binding rules for small sewage discharges determine when treated wastewater can enter surface water without an environmental permit. Discharges to ground have separate requirements. A BioDisc must meet the applicable conditions regardless of its treatment capability.
Klargester BioDisc Sizes: BA, BAx, BB and BC
The domestic Klargester BioDisc range includes four models with different wastewater treatment capacities. The table below compares their specifications:
| Model | Population equivalent | Maximum daily flow | Maximum BOD5 load |
| BA | 6 PE | 1.2 m³/day | 360 g/day |
| BAx | 9 PE | 1.8 m³/day | 540 g/day |
| BB | 12 PE | 2.4 m³/day | 720 g/day |
| BC | 18 PE | 3.6 m³/day | 1,080 g/day |
Figures from the official Klargester BioDisc technical specifications. BOD5 measures the oxygen required to break down biodegradable organic matter over five days.
Population equivalent (PE) represents the wastewater loading a system is designed to handle, not simply the number of people currently occupying the property.
Choosing the correct model requires considering the property's design capacity, including bedrooms, potential occupancy, additional dwellings and planned extensions. Holiday accommodation and commercial activities may introduce different wastewater demands.
The Environment Agency's sizing requirements state that treatment systems must accommodate maximum expected sewage volumes, with new installations following British Water's Flows and Loads guidance.
Why BioDisc Inlet Invert Depth Matters
Inlet invert depth is the vertical distance from finished ground level to the bottom of the incoming drainage pipe. It determines whether wastewater can enter the treatment plant at the required level.
Klargester offers different inlet configurations:
- BA, BAx and BB: 450 mm, 750 mm or 1,250 mm.
- BC: 600 mm or 1,100 mm.
These options matter particularly when replacing an existing sewage system, where incoming pipe levels may already be fixed.
Capacity alone cannot determine the correct BioDisc model. The inlet depth, outlet levels, available installation space and ground conditions must also suit the property's drainage arrangement.
What Is Involved in Installing a Klargester BioDisc?
Installing a Klargester BioDisc sewage treatment plant requires careful site assessment, drainage planning and compliance checks before excavation begins.
The main considerations include:
- Plant capacity: Calculate the expected wastewater loading.
- Drainage levels: Check incoming pipe invert depth and outlet requirements.
- Discharge route: Confirm a suitable drainage field or lawful surface water discharge before installation.
- Ground conditions: Assess soil suitability, groundwater levels and excavation stability.
- Tank installation: Follow manufacturer requirements for excavation, bedding, backfilling and structural support.
- Electrical supply: Arrange a suitable connection for the motor and controls.
- Ventilation and access: Provide adequate ventilation and safe access for servicing and desludging.
- Commissioning: Check mechanical operation, connections and system performance.
At Drain Surgeons, we assess private drainage layouts and wastewater treatment requirements when you need to install, replace or upgrade an existing system.
Where Can a Klargester BioDisc Discharge?
Treated wastewater from a Klargester BioDisc can enter a suitable watercourse or be discharged into the ground through a drainage field. The best option for your property depends on the available outlet, site conditions, and environmental restrictions.
Discharge to Surface Water
Rivers, streams and certain drainage ditches can receive treated BioDisc effluent, provided they meet the necessary conditions.
In England, qualifying small sewage discharges to surface water are limited to 5 cubic metres per day without an environmental permit.
The receiving water must have sufficient flow throughout the year, except during drought or unusually prolonged dry conditions. Seasonal ditches that regularly dry out are unsuitable.
Other considerations include proximity to protected habitats, existing discharge points and the potential impact on water quality. Even where a watercourse is nearby, its suitability needs to be established before connecting the outlet.
Discharge to Ground
Where a suitable watercourse is unavailable, underground disposal through a sewage drainage field may be possible. Qualifying small discharges to ground are limited to 2 cubic metres per day without an environmental permit.
Perforated pipes distribute the treated wastewater across underground trenches, allowing it to filter through the soil. Successful operation depends on suitable permeability, sufficient separation from groundwater and adequate space.
Unlike a conventional rainwater soakaway, which collects surface runoff, a sewage drainage field is designed to provide further treatment as effluent passes through the ground.
Soil testing and site assessment help establish whether this arrangement is practical. Where neither option meets the necessary conditions, an alternative discharge solution or environmental permit may be required.
Klargester BioDisc Servicing and Desludging
Keeping your Klargester BioDisc in good condition requires regular equipment inspections and sludge removal. These are separate tasks, each with a different purpose.
- Routine owner checks: Look out for unusual noises, warning alarms, leaks or changes in system operation.
- Professional servicing: An engineer checks the motor, gearbox, drive components, rotor, bearings, electrical connections and alarms, depending on the model.
- Desludging: A specialist contractor removes accumulated sludge from the designated settlement chambers for authorised disposal.
Servicing should follow the maintenance instructions for your particular unit, with any worn or faulty components repaired promptly.
How Often Does a Klargester BioDisc Need Emptying?
There is no fixed Klargester BioDisc emptying frequency suitable for every installation. Sludge builds up at different rates depending on the plant's capacity, occupancy and wastewater usage.
While annual removal may be appropriate for some installations, older BioDisc manuals specify shorter intervals for certain models. Check your unit's documentation and arrange desludging before sludge levels interfere with treatment.
Can You Completely Empty a BioDisc?
Not every chamber should be emptied during desludging. The biological growth attached to the rotating discs is essential for breaking down organic waste.
Older manufacturer instructions distinguish between settlement compartments, where sludge collects, and the biological rotor area, which requires different handling.
Incorrect emptying can disturb the treatment process or leave components operating under unsuitable conditions. An experienced sewage treatment contractor should follow the procedure specified for your BioDisc model, including any required refilling before restarting the system.
Common Klargester BioDisc Problems and What They May Indicate
Mechanical faults, changes in wastewater quality and unusual odours can indicate that your Klargester BioDisc needs attention. The following table outlines potential causes, although identifying the actual fault requires an inspection.
| Problem | Possible areas to investigate |
| Rotor not turning | Power supply, motor, gearbox, drive belt or chain, pulleys, bearings, obstructions or controls |
| BioDisc alarm operating | Loss of rotation, electrical faults or other monitored conditions, depending on the model |
| Strong sewage smell | Excess sludge, grease accumulation, inadequate ventilation, treatment interruption or hydraulic overload |
| Poor quality effluent | Excessive loading, incorrect sizing, rotor failure, sludge buildup or disruption of biological activity |
| Repeated drive problems | Worn belts, incorrect tension, pulley misalignment, damaged bearings or faulty drive components |
A stationary rotor requires prompt attention because the rotating discs must remain operational for effective biological treatment. Similarly, an activated alarm signals a condition that needs investigation, but does not necessarily identify the faulty component.
Repeated drive failures deserve closer investigation. A displaced belt, for example, may be caused by incorrect pulley alignment or tension rather than wear alone. Replacing it without correcting the underlying issue can lead to another breakdown.
At Drain Surgeons, we provide sewage treatment plant inspection and servicing to help identify mechanical faults, investigate recurring wastewater problems and determine the repairs your system needs.
What Should You Avoid Putting Into a Klargester BioDisc?
Your Klargester BioDisc relies on living microorganisms to treat sewage, so what enters the drains matters. Certain materials can cause blockages, interfere with biological activity or damage treatment components.
Avoid disposing of the following through your wastewater system:
- Wet wipes, sanitary products and nappies: These can obstruct pipes and mechanical components, even when labelled flushable.
- Fats, oils and grease: They can accumulate inside the plant and restrict normal wastewater flow.
- Paint, solvents and pesticides: These substances may harm the microorganisms responsible for treatment.
- Large quantities of bleach or strong disinfectants: Excessive use can disturb the biological treatment process.
Normal household cleaning products, including washing detergents and diluted disinfectants, are generally acceptable when used as directed and in reasonable quantities. Avoid pouring concentrated chemicals directly into drains, and follow the instructions for your particular BioDisc model.
Klargester BioDisc Cost and Running Expenses
The Klargester BioDisc cost extends well past the treatment plant's purchase price. Your total investment depends on installation requirements, ongoing maintenance and eventual component replacements.
The main expenses include:
- Equipment: BioDisc purchase and any additional pumping equipment.
- Installation: Excavation, tank positioning, backfilling and commissioning.
- Drainage: Connecting pipework, drainage field construction or suitable outlet arrangements.
- Electrical work: Power supply, wiring and controls.
- Routine running costs: Electricity, professional servicing and desludging.
- Repairs: Replacement motors, bearings, drive components and other worn parts.
Difficult access, rock excavation, high groundwater or deeper drainage connections can considerably increase installation costs. Removing an existing septic tank adds further expense.
Electricity consumption also varies. The Klargester BioDisc specifications show different motor ratings across models, so annual running costs should reflect your particular unit and electricity tariff rather than a generic estimate.
Buying a House With a Klargester BioDisc: What Should You Check?
Before purchasing a property with a Klargester BioDisc, establish its condition, maintenance history and discharge arrangements. Start by identifying the model, approximate installation date, and serial number, where available.
Ask the seller for:
- Installation records: Commissioning documents, owner's manual and Declaration of Performance, where available.
- Maintenance history: Service reports, desludging records and previous repairs.
- Operating information: Alarm instructions, control details and known faults.
- Discharge details: Outlet location, discharge type and any required environmental permit.
- Drainage field records: Layout plans and installation details if effluent enters the ground.
Check where the effluent goes, not just whether the motor runs. An operational plant may still have a damaged outlet or unsuitable drainage field. Consider a specialist drainage inspection before exchanging contracts, particularly when records are incomplete or the discharge location is unclear.
Give Your Klargester BioDisc the Care It Needs
A Klargester BioDisc is a long-term investment in your property's wastewater management. Knowing when to arrange servicing, investigate a fault or consider replacement can save you from unexpected disruption and unnecessary expenses.
At Drain Surgeons, we help you make the right decisions for your system. From sewage treatment plant installation and servicing to fault investigation and repairs, our team can recommend solutions suited to your property's requirements. We also examine connected drainage where necessary, since restricted inlet pipes or damaged outlets can sometimes be mistaken for treatment plant faults.
Whether you have recently moved into a property with a BioDisc or have maintained one for years, reliable professional support makes ownership easier.
Contact Drain Surgeons to discuss your system, arrange an inspection or get advice on the next steps.
FAQs
Is a Klargester BioDisc the same as a septic tank?
No. Although both handle domestic sewage, they use different treatment methods. A septic tank mainly separates solids and allows partial decomposition, whereas a BioDisc provides additional biological treatment through powered rotating media. This makes the BioDisc suitable for certain discharge arrangements where septic tank effluent would not be acceptable.
How many people can a Klargester BioDisc serve?
Domestic Klargester BioDisc models have design capacities ranging from 6 to 18 population equivalent (PE). The BA serves a design load of 6 PE, BAx 9 PE, BB 12 PE and BC 18 PE. These ratings represent wastewater treatment capacity rather than a guarantee based solely on the number of residents.
How often should a Klargester BioDisc be serviced?
Domestic BA, BAx, BB and BC models are commonly scheduled for professional servicing annually, although requirements can differ according to the unit's age, configuration and operating conditions. Larger installations may need more frequent visits. Check the specific handbook and warranty conditions to establish the correct schedule for your plant.
How often should a BioDisc be emptied?
The emptying schedule depends on how quickly sludge accumulates in the settlement chambers. Some older BioDisc models require removal every few months, while others have longer intervals. Increased occupancy or unusually high wastewater loading can shorten the time between visits. Follow the schedule specified for your particular installation.
Why has my Klargester BioDisc stopped turning?
Check whether there has been a power interruption or whether the electrical circuit has tripped. Other possible causes include a faulty motor, damaged drive components, seized bearings or an obstruction. Avoid attempting repairs around moving or electrical equipment. Arrange an engineer's inspection if rotation does not resume normally.
What happens to a BioDisc during a power cut?
The rotating discs stop, interrupting normal biological treatment. On gravity discharge systems, wastewater may continue flowing through the plant, but treatment quality will gradually decline. Pumped outlet systems present an additional concern because wastewater levels can rise and eventually overflow. Once electricity returns, check that rotation and any discharge pumps have restarted correctly.
Can you switch off a Klargester BioDisc?
You should not routinely switch off an operating BioDisc to save electricity. The biological treatment process depends on regular disc rotation, even when household water usage is low. Extended shutdowns can affect treatment performance and restart conditions. For prolonged property vacancies, follow the manufacturer's shutdown instructions or seek professional advice.
Can a Klargester BioDisc discharge into a stream?
Yes, provided the stream is suitable and the proposed discharge is authorised under the applicable requirements. Factors include water flow, discharge volume, treatment performance and environmental sensitivity. A stream that regularly dries out may not qualify for discharge without a permit. Approval should never be assumed simply because the effluent has undergone treatment.
Does a Klargester BioDisc need a drainage field?
Not necessarily. A drainage field is normally required when treated effluent is discharged into the ground. Where the plant has an acceptable surface water outlet, a conventional underground drainage field may not be needed. The correct arrangement depends on the site's discharge destination and conditions rather than the BioDisc model alone.
How long does a Klargester BioDisc last?
There is no guaranteed lifespan for every BioDisc installation. Tank integrity, environmental conditions, wastewater loading and maintenance history all influence durability. Motors, bearings and other mechanical components may require replacement during the plant's working life. A professional condition assessment is more useful than relying on a fixed age when deciding whether to repair or replace an older system.